1KVA – 30KVA
- Active Power Factor Correction.
- Single Inverter Card Including Power Device.
- Communication.
- Hot Stand By.
- Customization Available.
- Scalable Battery.
- LCD/LED Display.
DES Online UPS
No. | Model | VDC | 1/3 | Battery Bank |
1 | 1KVA Hi - Frequency | 12V | 1/1 | External |
2 | 2KVA with PFC Charger and Isolation | 96V | 1/1 | External |
3 | 3KVA with PFC Charger and Isolation | 96V | 1/1 | External |
4 | 5KVA with PFC Charger and Isolation | 120V | 1/1 | External |
5 | 7.5KVA with PFC Charger and Isolation | 180V | 1/1 | External |
6 | 10KVA with PFC Charger and Isolation | 180V | 1/1 | External |
7 | 10KVA with PFC Charger and Isolation | 360V | 3/1 | External |
8 | 15KVA with PFC Charger and Isolation | 360V | 3/1 | External |
9 | 15KVA with PFC Charger and Isolation | 360V | 3/3 | External |
Technical Specifications
TECHNICAL SPECIFICATION | |||||||||||||
NXT GEN PFC (Half Electricity Consuming) Series : 1 Phase in- 1 Phase Out | |||||||||||||
Input | Power Rating | 1KVA | 2 & 3 KVA | 5 & 6 KVA | 7.5 KVA | 10 KVA | |||||||
Voltage Range | V | 160 to 280 | |||||||||||
Frequency | Hz | 50 +/ - 5% | |||||||||||
Input Power Factor | 0.9 @ 96VDC,0.82 @180VDC | ||||||||||||
Charger Topology | Buck- IGBT | ||||||||||||
Electrical Connection | Input | 2.5 Sq mm. | 4 Sq mm. | 6 Sq mm. | 8 Sq mm. | 10 Sq mm | |||||||
Output | 1.5 Sq mm. | 2.5 Sq mm. | 4 & 6 S Q mm. | 6 Sq mm. | 8 SqMM. | ||||||||
Batt. | 96V | 4 Sq mm. | 8 Sq mm. | NA | NA | NA | |||||||
120V | 4 Sq mm. | 6 Sq mm. | 16 Sq mm. | NA | NA | ||||||||
180V | 4 Sq mm. | 4 Sq mm. | 6 Sq mm. | 10 Sq mm. | 12 Sq mm. | ||||||||
Earth | 6 Sq mm. | 10 Sq mm. | |||||||||||
Output | Power factor | Lag | 0.8 | ||||||||||
Voltage | V | 230 | |||||||||||
Voltage Regulation | % | +/- 1 | |||||||||||
Frequency | Hz | 50 | |||||||||||
Frequency Regulation | Hz | +/- 0.05 | |||||||||||
Wave Form | Pure Sine wave | ||||||||||||
Transient Response | % | <8_10%`90%(Liner Load) | |||||||||||
Voltage Harmonic | % | <3 (Liner Load) | |||||||||||
Over Load Capacity | 100 to 150 % :18 Sec 150 to 300 % :20 msec <300 immediately |
||||||||||||
Crest Factor | 3 : 1 | ||||||||||||
Audible Warning | Battery Back-up Ending | Intermittent | |||||||||||
Over Load | Continuous | ||||||||||||
Display | LED | UPS on # Battery High/ Low # O/P High/Low # Charging ON # Mains Low/ High. | |||||||||||
Protection | Output Over Voltage# Output Under Voltage# Over load# Output Short Circuit# Battery Over Voltage# Battery under Voltage, Input Low/ High. | ||||||||||||
Parameter | 7 Segment (up to 7.5KVA) | Output Voltage Meter | |||||||||||
LCD Display (10 kva) | Input Voltage & Frequency, Output Voltage & Frequency, Load %, Charging Current, DC Voltage | ||||||||||||
Interface | Db9 | Rs 232/USB Port, SNMP (OPTIONAL) | |||||||||||
Others | Battery Start | Standard | |||||||||||
Cabinet wheals | Standard | ||||||||||||
Extended Battery Charging | Optional | ||||||||||||
Static By Pass | Optional/ Default Rotary Switch | ||||||||||||
Overall | Efficiency (ac-ac) | % | >85** (Full Load) | ||||||||||
Transfer Time | ms | 0 | |||||||||||
Temperature | C | 0`45 | |||||||||||
Humidity | % | 5-95 (non- Condensed) | |||||||||||
Dimension | Width | Inch | 10 | 10 | 11 | 13 | 13 | ||||||
Height | Inch | 16.5 | 16.5 | 21 | 27 | 27 | |||||||
Length | Inch | 22.5 | 22.5 | 24 | 31 | 31 |